A cost-effective, off-the-shelf solution for small wastewater treatment plants
The TrojanUV3000®PTP (Packaged Treatment Plant) is ideally suited to treat flows up to 3 MGD (473 m3/hr). It is pre-engineered for quick, economical installation and is designed with proven components to provide a dependable UV solution for small wastewater treatment applications.
The TrojanUV3000PTP can be installed into existing chlorine contact tanks and effluent channels. It comes pre-tested, pre-assembled and pre-wired to minimize installation costs, and can also be equipped with prefabricated stainless-steel channels with built-in weirs. Channels are easily integrated with existing flanged piping using transition boxes.
Space-saving electronic lamp drivers are housed right in the modules, not in separate external cabinets – this minimizes the footprint of the UV system and eliminates the need for air-conditioning. Lamp drivers are cooled by convection and each UV module includes a UV lamp status indicator for at-a-glance monitoring.
Modules are lightweight and can be individually removed for periodic sleeve cleaning and lamp change-outs. An optional mobile cleaning rack simplifies maintenance procedures.
The TrojanUV3000PTP has been validated through microbial testing. Through this testing, performance data has been generated for UV dose delivery to inactivate microorganisms Escherichia coli (E. coli ) and fecal coliform.
System Characteristics | TrojanUV3000PTP |
Typical Applications | Up to 3 MGD (473 m3/hr) |
Lamp Type | Low-pressure |
Lamp Driver Type | Electronic; non-variable |
Input Power Per Lamp | 45 or 87.5 Watts |
Lamp Configuration | Horizontal, parallel to flow |
Module Configuration | 2 or 4 lamps per module |
Bank Configuration | Up to 10 modules per bank |
Channel Configurations | |
Lamp Banks in Series | Up to 2 |
Channel Options | Stainless Steel (Trojan option) or Concrete (by others) |
Flanged Transition Connections | Optional for stainless steel channels |
U-Turn Connector Box | Optional for stainless steel channels |
Level Control Device Options | Fixed weir |
Enclosure Ratings | |
System Monitor/Control Center | Fibreglass |
Lamp Driver Enclosure | TYPE 6P (IP67) |
Lamp Driver Cooling Method | Convection; no air conditioning or forced air required |
Installation Location | Indoor or outdoor |
System Monitoring & Controls | |
Controller | Optional; Monitoring only |
UV Intensity Monitoring | Optional |
Inputs Required | None |
Local Status Indication | Lamp Age (hours) UV Intensity (mW/cm2) |
Remote Alarms | UV Intensity (4-20 mA) |
Location | Indoor or outdoor |
Maximum Distance from UV Channel | 15 ft. (4.5 m) |
Electrical Requirements | |
Power Distribution | Individual GFI Receptacles for UL system. Provided by third-party for CE system |
Quantity Required | 1 receptacle per 2 modules for UL system. CE system determined by third-party electrical code |
Power Input | 120V, single phase for UL system. 230V, single phase for CE system |
Have questions? Call us at 1 (888) 220-6118 or complete the form below.