TrojanUVFit

In-pipe UV wastewater treatment for non-potable reuse

Treating Filtered Effluent

Depending on site and design conditions, wastewater treatment plants producing filtered effluent sometimes prefer a treatment solution using in-pipe (also called closed-vessel) UV chambers. The TrojanUVFit® offers an effective, compact, and energy-efficient solution for non-potable reuse with a streamlined hydraulic profile that won’t break head in the treatment process. The system is available in multiple configurations to treat a wide range of flow rates, up to 7 MGD per chamber.


    TrojanUVFit Logo

    Key Features & Benefits

    Compact Design and Installation Flexibility

    The compact chamber footprint simplifies indoor retrofit installations and can also be installed in parallel or in series, making it simple to incorporate redundancy or future expansion needs. UV lamps and sleeves are fully serviceable from the chamber end cap, allowing the system to be installed against walls, other equipment or piping.

    TrojanUVFit in North Lake, Idaho

    The TrojanUVFit Sleeve Cleaning system

    Robust Sleeve Cleaning System

    The sleeve cleaning system minimizes fouling of quartz sleeves, ensuring the maximum UV output is available. The system works automatically at preset intervals without operator involvement and without interrupting treatment.

    Reliable Performance and Easy Maintenance

    UV lamps, quartz sleeves, lamp drivers, sensors and the sleeve cleaning system have been proven reliable and are operating in hundreds of installations. Internal components are all easily accessed from the end cap which, when removed, automatically deactivates lamps for operator safety. Routine procedures, such as lamp change-outs are simple and require minimal time.

    An operator replacing a TrojanUVFit lamp

    A TrojanUVFit chamber and control panel

    3rd Party Validation

    The TrojanUVFit has been validated through microbial testing. Through this testing, performance data has been generated for UV dose delivery to inactivate Poliovirus, Escherichia coli (E. coli ) and fecal coliform.

    For reuse applications in California, the California Department of Public Health has approved several TrojanUVFit models for Title 22 reuse applications.

    System Specifications

    Model

    04AL20

    08AL20

    18AL40

    32AL50

    Number of Lamps

    4

    8

    18

    32

    Lamp Type

    High-efficiency, High-output, Low-pressure Amalgam

    Sleeve Wiping

    Automatic wiping system

    Lamp Driver

    Electronic, constant output (100% power) or electronic, variable output (60 to 100% power)

    Chamber

     

    Materials of Construction

    316L Stainless Steel

    Flange Size (ANSI/DIN), inches (mm)

    6 (150)

    10 (250)

    12 (300)

    Outlet Flange Orientation

    Multiple orientations available 3, 6, 9 or 12 o’clock position

    Approx. Chamber Length, inches (mm)

    80 (2032)

    80 (2032)

    82 (2083)

    90 (2286)

    Max. Operating Pressure, PSI (bar)

    150 (10)

    150 (10)

    150 (10)

    100 (6.8)

    Dry Chamber Weight, lbs (kg)

    107 (49)

    115 (52)

    400 (181)

    1600 (726)

    Wet Chamber Weight, lbs (kg)

    230 (105)

    877 (398)

    2200 (998)

    Power Distribution Center (PDC)

     

    Electrical Supply

    Standard:

    Single phase, 2 wire

    + gnd, 50/60 Hz L-L

    120V

    N/A

    N/A

    N/A

    N/A

    208V

    Yes

    Yes

    Yes

    Yes

    240V

    Yes

    Yes

    Yes

    Yes

    3 Phase, 4 wire +

    gnd, 50/60 Hz

    400/230V

    N/A

    N/A

    Yes

    Yes

    Dimensions (H x W x D) inches (mm)

    Type 12

     

    30 x 16 x 10 (760 x 410 x 250)

     

    36 x 30 x 10

    (920 x 760 x

    250)

    60 x 36 x 10

    (1520 x 920 x

    250)

    Type 3R

    Type 4X

    30 x 24 x 10 (760 x 610 x 250)

    60 x 36 x 12

    (1520 x 920 x

    305)

    Material

    Type 12

    Painted Mild Steel

    Type 3R

    Painted Mild Steel

    Type 4X

    304 Stainless (1.4301 in Europe)

    Panel Rating

    NEMA 12, 3R or 4X

    NEMA 12 or 4X

    Network Interface

    Modbus RTU RS485, Modbus TCP/IP, AB Ethernet I/P, ProfiNet

    System Control Center (SCC)

     

    Panel is Required/Optional

    N/A (requires only PDC)

    Optional

    Electrical

    N/A (see PDC)

    Two (2) Supplies of 120 V single phase, 2 wire plus

    ground, 60 Hz, 1.2 kVA (one (1) for the PLC, one (1) for

    lights & heater)

    Material

    Type 12

    Painted Mild Steel

    Type 4X

    Stainless(1.4301 in Europe)

    Panel Rating

    N/A (see PDC)

    NEMA 12 or 4X

    Typical Outputs Provided

    Chamber status, common alarms and SCADA communication

    Network Interface

    Modbus RTU RS485, Modbus TCP/IP, AB Ethernet I/P, ProfiNet

    Related Resources

    TrojanUVFit Brochure

    TrojanUVFit Brochure

    Download
    TrojanUV Service & Parts Brochure

    TrojanUV Service & Parts Brochure

    Download

     

    Replacement Parts

    TrojanUV 794447-0GN, UV Lamp
    794447-0GN
    Price: Contact Us
    917067, Lamp Driver
    917067
    Price: Contact Us
    TrojanUV Lamp, 794447-0RD
    794447-0RD
    Price: Contact Us
    793024, Quartz Sleeve
    793024
    Price: Contact Us

    We're Here to Help